NSN 5925-00-214-0461
Overload Switch
Multipole-single actuator type body style, metal case material, moderately rugged fragility factor, pole quantity: 3.
Manufacturer part number 7900284-25 for national stock number 5925002140461.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-214-0461.
-
MPN or Model
7900284-25
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.4 lb -
Body Style
Multipole-single actuator type -
Bushing Length
Between 0.365 inches and 0.390 inches -
Body Length
1.562 inches -
Body Width
1.937 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
Between 0.865 inches and 0.885 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.594 inches and 0.656 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.828 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.375 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 at 200 pct all locations and 5.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Hermetically sealed and fungus resistant and salt spray proof and moisture resistant -
Frequency In Hertz
400.0 all locations -
Unpackaged Unit Weight
4.500 ounces -
Precious Material And Location
Contact surfaces silver -
Precious Material
Silver -
Thread Series Designator
Unef -
Terminal Type And Quantity
6 wire hook
More from these suppliers
- 5925-00-247-6979 MPN AM3336HKMG6-25-A-250-14-400Circuit Breaker
- 5925-00-429-1657 MPN AM3-C2-A-10-2Circuit Breaker
- 5925-00-500-8618 MPN AM333MG6-50-208-15-400Circuit Breaker
- 5925-00-644-5260 MPN PC411TSCircuit Breaker
- 5925-00-775-3614 MPN AM12MG6-1-50VDC5Circuit Breaker
- 5925-00-801-5417 MPN AM13HKMG3-1-0-115VAC4Circuit Breaker
- 5925-00-890-9398 MPN AM33HK71-168-2MG6Circuit Breaker
- 5925-01-192-7253 MPN AM2-Z397-1Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-214-0461 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
7900284-25 | Lockheed Martin Corporation |
SM333-5-250VAC400-1W017-10018 | Eaton Corp |
AP112-1304-25 | Sensata Technologies Maryland, Inc |