NSN 5925-01-188-1170
Overload Switch
Multipole-single actuator type body style, plastic case material, 2 poles, thready qty per inch (tpi): 32.
Manufacturer part number APL-11-1-50-202-M for national stock number 5925011881170.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-188-1170.
-
MPN or Model
APL-11-1-50-202-M
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Body Style
Multipole-single actuator type -
Body Length
2.448 inches -
Body Width
2.484 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.938 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
Boss Height
0.156 inches -
Mounting Surface To Terminal End Distance
2.453 inches -
Pole Quantity
2 -
Mounting Facility Type And Quantity
4 threaded hole -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
2.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
100.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Instantaneous all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations -
Ultimate Trip Time Per Pole In Seconds
0.015 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 push-pull -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
External Actuator Linkage Arrangement
One and two linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.032 at 150 pct all locations and 150.000 at 150 pct all locations -
Inclosure Protection Type For Which Designed
Moisture resistant and corrosion resistant and shock resistant and vibration resistant -
Thread Series Designator
Unc -
Terminal Type And Quantity
4 threaded stud
More from these suppliers
- 5925-00-443-9425 MPN 70-383-1Circuit Breaker
- 5925-00-484-7644 MPN AM2-A8-A-7.5-250AC-10Circuit Breaker
- 5925-00-622-0345 MPN JL1-A2-A-2-3Circuit Breaker
- 5925-00-755-5261 MPN XAM666MG3-35AMP208VACTDC14Circuit Breaker
- 5925-00-925-2164 MPN G330011S17Circuit Breaker
- 5925-00-954-6419 MPN 72-125-68MG6Circuit Breaker
- 5925-00-967-6476 MPN 1163MG4-5-250VAC60C1SCircuit Breaker
- 5925-00-989-8690 MPN AM17-3A115V60CYC56Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-188-1170 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
APL-11-1-50-202-M | Sensata Technologies Maryland, Inc |
AM2-B3-A-2-P | Heinemann Electric Canada Ltd Divof |
AM2-B3-A-2-P | Eaton Corp |
Stock Check
![](/public/images/partscage_shelf3.png)