Overload Switch
Multipole-single actuator type body style, plastic case material, single pole, double throw switch contact arrangement, pole quantity: 3.
Manufacturer part number TED134C5070ST13RSAS2AB1LS for national stock number 5925002313585.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-231-3585.
-
MPN or Model
TED134C5070ST13RSAS2AB1LS
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
2.3 lb -
Body Style
Multipole-single actuator type -
Body Length
6.312 inches -
Body Width
4.125 inches -
Body Height
3.188 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
5.250 inches -
Center To Center Distance Between Terminals Parallel To Width
1.375 inches -
Unthreaded Mounting Hole Diameter
0.188 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
4.880 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.375 inches -
Boss Height
0.125 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
4 unthreaded hole -
Storage Type
General purpose warehouse -
Maximum Continuous Load Current Rating Per Pole
70.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
480.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
18000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Instantaneous all locations and time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
Auxiliary Switch Function And Quantity
1 alarm -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
0.025 at 150 pct all locations and 9.000 at 150 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant -
Trip Release Ambient Tempurature Rating
50.0 degrees celsius all locations -
Switch Terminal Type
Solder stud -
Switch Current Rating And Type In Amps
6.0 ac and 0.25 dc -
Switch Voltage Rating And Type In Volts
480.0 ac and 250.0 dc -
Frequency In Hertz
60.0 all locations -
Terminal Type And Quantity
1 wire lead and 6 compression
More from these suppliers
- 5930-00-519-9497 MPN 383A612P1Switch Latch
- 5930-01-423-8203 MPN CR104TR20AORO1Push Switch
- 5930-01-444-3595 MPN TH2261DCElectronic Switch
- 5925-00-441-7918 MPN TFJ236175WL/W FUNGUSTMOISTURECircuit Breaker
- 5925-00-841-9425 MPN TEF134050WLCircuit Breaker
- 5925-01-187-0694 MPN TEC36015WLCircuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-231-3585 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
TED134C5070ST13RSAS2AB1LS | General Electric Co |