NSN 5925-00-408-8847

Overload Switch

About this product

Multipole-single actuator type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.

Manufacturer part number GB3-A2A3A3-5-9 for national stock number 5925004088847.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-00-408-8847.

  • MPN or Model

    GB3-A2A3A3-5-9

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Body Style
    Multipole-single actuator type
  • Body Length
    Between 5.990 inches and 6.010 inches
  • Body Width
    Between 4.490 inches and 4.510 inches
  • Case Material
    Plastic
  • Center To Center Distance Between Terminals Parallel To Length
    Between 5.115 inches and 5.135 inches
  • Center To Center Distance Between Terminals Parallel To Width
    Between 1.490 inches and 1.510 inches
  • Unthreaded Mounting Hole Diameter
    Between 0.256 inches and 0.276 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
    Between 4.583 inches and 4.603 inches
  • Switch Contact Arrangement
    Single pole, double throw
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
    Between 1.490 inches and 1.510 inches
  • Fragility Factor
    Moderately rugged
  • Boss Height
    Between 0.177 inches and 0.197 inches
  • Mounting Surface To Terminal End Distance
    Between 4.427 inches and 4.447 inches
  • Pole Quantity
    3
  • Arc Quenching Method
    Magnetic blowout
  • Mounting Facility Type And Quantity
    4 unthreaded hole
  • Storage Type
    General purpose warehouse
  • Special Handling Feature
    Magnetic
  • Maximum Continuous Load Current Rating Per Pole
    5.0 amperes ac all locations
  • Operating Voltage Type And Rating Per Pole In Volts
    480.0 ac all locations
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    10000.0 ac all locations
  • Circuit Protection Type
    Overcurrent all locations
  • Trip Release Method
    Magnetic-hydraulic all locations
  • Trip Release Characteristic
    Time delay all locations
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    125.0 all locations
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    1 toggle
  • Actuator Function
    Trip-reset
  • Actuator Position Designation
    At pole two
  • Auxiliary Switch Function And Quantity
    1 alarm
  • Internal Trip Release Configuration
    Series trip all locations
  • Switch Location And Position Designation
    External at pole one
  • Trip Delay Time In Seconds Per Rated Continuous Current
    30.000 at 200 pct all locations and 250.000 at 200 pct all locations
  • Inclosure Protection Type For Which Designed
    Fungus resistant and moisture resistant and shock resistant and vibration resistant
  • Switch Terminal Type
    Tab, solder lug
  • Switch Current Rating And Type In Amps
    15.0 ac and 0.25 dc
  • Switch Voltage Rating And Type In Volts
    460.0 ac and 250.0 dc
  • Frequency In Hertz
    60.0 all locations
  • Unpackaged Unit Weight
    4.000 pounds
  • Terminal Type And Quantity
    6 threaded stud
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-00-408-8847 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925004088847

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
GB3-A2A3A3-5-9 Eaton Corp
Stock Check
Availability of this NSN has not been updated recently. Submit the pricing and availbility form above to receive an up to date quote.