NSN 5925-00-500-6743
Overload Switch
0.125 inches mounting slot width, metal case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number SKA-21 for national stock number 5925005006743.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-500-6743.
-
MPN or Model
SKA-21
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Mounting Slot Width
0.125 inches -
Case Material
Metal -
Fragility Factor
Moderately rugged -
Pole Quantity
1 -
Mounting Facility Type And Quantity
4 slot -
Storage Type
General purpose warehouse -
Maximum Continuous Load Current Rating Per Pole
3.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
30.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
600.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Time delay single location -
Reset Method
Automatic -
Internal Trip Release Configuration
Series trip single location -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location -
Unpackaged Unit Weight
1.000 ounces -
Terminal Type And Quantity
2 tab, solder lug
More from these suppliers
- 1680-00-226-6281 MPN 1433-623304Rotary Electro-mechanical Actuator
- 6105-00-356-6677 MPN 400052Electric Brake Disk
- 4920-00-248-2538 MPN 903629-1Counter Pad
- 4820-00-307-6016 MPN 108158-1-4Fluid Pressure Regulating Valve
- 1560-00-390-6239 MPN 2200662-1Air Heating System Duct Assembly
- 5930-00-403-8848 MPN 527547-2Sensitive Switch
- 4920-00-870-1382 MPN 257562-29Valve Test Adapter
- 5930-00-947-2504 MPN 139347-1Electrical Switch Retainer
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-500-6743 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
SKA-21 | Sensata Technologies, Inc |
26827 | Honeywell International Inc. |
SKA21 | Triumph Gear Systems, Inc. |
26827 | Ontic Engineering And Manufacturing, |