NSN 5925-00-549-2433
Overload Switch
Plastic case material, 3 poles, 32 thready qty per inch (tpi), maximum continuous load current rating per pole: 60.0 amperes ac all locations.
Manufacturer part number 3XAM1516MG3-60-250-2-50 for national stock number 5925005492433.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-549-2433.
-
MPN or Model
3XAM1516MG3-60-250-2-50
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Length
3.719 inches -
Body Width
3.052 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
3.063 inches -
Center To Center Distance Between Terminals Parallel To Width
1.031 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.031 inches -
Boss Height
0.156 inches -
Mounting Surface To Terminal End Distance
3.359 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
6 threaded hole -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
60.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Ultimate Trip Time Per Pole In Seconds
20.000 all locations and 65.000 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
5.000 at 200 pct all locations and 18.000 at 200 pct all locations and 0.600 at 500 pct all locations and 1.700 at 500 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Frequency In Hertz
50.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5925-00-408-8845 MPN GB3-A2A3A3-20-9Circuit Breaker
- 5925-00-556-3601 MPN AM13MG30-5AMP117VAC4Circuit Breaker
- 5925-00-878-6034 MPN AM333MG6-4.1-115VAC-14-400Circuit Breaker
- 5925-00-944-8650 MPN 79-129-1Circuit Breaker
- 5925-01-096-4693 MPN HE3C2-0-05-051Circuit Breaker
- 5925-01-237-5755 MPN AM3-A2A3A3-A-40-2Circuit Breaker
- 5925-01-265-7741 MPN JA1-V3-10-2Circuit Breaker
- 5925-01-322-9078 MPN HM2-M3-5-ACircuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-549-2433 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
3XAM1516MG3-60-250-2-50 | Eaton Corp |