NSN 5925-00-620-3968
Overload Switch
Instantaneous trip settings 600 amp ac and 800 amp dc.
Manufacturer part number ETN1061 for national stock number 5925006203968.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-620-3968.
-
MPN or Model
ETN1061
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Body Length
4.125 inches -
Body Width
3.344 inches -
Body Height
3.375 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
2.625 inches -
Center To Center Distance Between Terminals Parallel To Width
1.125 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
0.500 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.937 inches -
Boss Height
0.125 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
2 threaded stud -
Thready Qty Per Inch (tpi)
24 -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac all locations and 15.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
125.0 ac all locations and 125.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations and 5000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Thermal-magnetic all locations -
Trip Release Characteristic
Instantaneous all locations and time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 all locations -
Ultimate Trip Time Per Pole In Seconds
3600.000 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole two -
External Actuator Linkage Arrangement
One, two, and three linked -
Thread Size
0.216 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 at 200 pct all locations and 100.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Shockproof and vibrationproof -
Trip Release Ambient Tempurature Rating
50.0 degrees celsius all locations -
Frequency In Hertz
60.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 quick disconnect, male
More from these suppliers
- 5930-01-197-4752 MPN ETN2755-00S01Toggle Switch
- 5930-01-407-2149 MPN 711221PC239Rotary Switch
- 5935-01-514-7573 MPN 766851-38Electrical Connector Retaining Plate
- 5950-01-525-7638 MPN G-4684Current Transformer
- 5975-01-327-3245 MPN 719127-B22Cable Marker Sleeve
- 5935-01-495-0745 MPN ERP4-300Electrical Plug Connector
- 5975-01-327-3245 MPN 719127-B22Cable Marker Sleeve
- 5975-01-327-3244 MPN 719127-B21Cable Marker Sleeve
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-620-3968 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
ETN1061 | Spd Electrical Systems, Inc |
Stock Check
![](/public/images/partscage_shelf3.png)