NSN 5925-00-812-0626
Overload Switch
Metal case material, 2 poles, 1600.0 amperes dc all locations maximum continuous load current rating per pole, operating voltage type and rating per pole in volts: 250.0 dc all locations.
Manufacturer part number 403D074SUB4SH1T03 for national stock number 5925008120626.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-812-0626.
-
MPN or Model
403D074SUB4SH1T03
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Case Material
Metal -
Unthreaded Mounting Hole Diameter
0.562 inches -
Pole Quantity
2 -
Mounting Facility Type And Quantity
8 unthreaded hole -
Maximum Continuous Load Current Rating Per Pole
1600.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
8000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Instantaneous all locations and time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
200.0 all locations -
Reset Method
Automatic -
Manual Actuator Type And Quantity
1 rotary -
Terminal Type And Quantity
4 bus bar -
Reference Number Differentiating Characteristics
Differentiated by pac cprg
More from these suppliers
- 5945-00-115-3594 MPN S1419427Stat Contact
- 5905-00-333-1151 MPN 35J730ITEM38Resistor
- 4820-00-337-1208 MPN 42J238PC7Fluid Valve Stem
- 5945-00-603-5591 MPN S503C553G34Thermal Relay
- 5950-00-645-4628 MPN S1406500Electrical Coil
- 5945-01-091-7276 MPN S432A289G50Overload Relay
- 5950-01-245-3344 MPN 597A750G08Current Transformer
- 5930-00-243-9186 MPN S1486696Electrical Switch
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-812-0626 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
403D074SUB4SH1T03 | Westinghouse Electric Corp |
403D074SH1T03 | Westinghouse Electric Corp |
Stock Check
![](/public/images/partscage_shelf3.png)