Overload Switch
Plastic case material, 3 poles, 32 thready qty per inch (tpi), maximum continuous load current rating per pole: 60.0 amperes ac first location.
Manufacturer part number 13211E6902 for national stock number 5925008546752.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-854-6752.
-
MPN or Model
13211E6902
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
2 lb -
Body Length
3.719 inches -
Body Width
3.052 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
3.063 inches -
Center To Center Distance Between Terminals Parallel To Width
1.031 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.031 inches -
Boss Height
0.156 inches -
Mounting Surface To Terminal End Distance
3.239 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
6 threaded hole -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
60.0 amperes ac first location -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Frequency In Hertz
60.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5925-00-367-7620 MPN AM12-20-250V60Circuit Breaker
- 5925-00-369-7747 MPN HE1B2-8-1Circuit Breaker
- 5925-00-529-0441 MPN HE1Z6-117Circuit Breaker
- 5925-00-687-0279 MPN AM13RSKMG6-0-5-250VAC60C4Circuit Breaker
- 5925-00-762-2526 MPN 79-102-29Circuit Breaker
- 5925-00-925-3607 MPN AM33MG6-3-250VAC60C5Circuit Breaker
- 5925-00-937-9572 MPN HM2-M3-12-ACircuit Breaker
- 5925-00-945-5418 MPN 2263SMG4-15-250-1-60Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-854-6752 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
13211E6902 | Cecom Lr Center |
53-135-2MG3TYPE3XAM1516 | Eaton Corp |
53-135-2MG3TYPE3XAM1516 | Eaton Corp |
Stock Check