NSN 5925-00-893-8383
Overload Switch
Multipole-multiple actuator type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number AM333HKMG6-2-250-4-60 for national stock number 5925008938383.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-893-8383.
-
MPN or Model
AM333HKMG6-2-250-4-60
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-multiple actuator type -
Body Length
2.500 inches -
Body Width
2.250 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.938 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.140 inches -
Mounting Surface To Terminal End Distance
2.611 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 at 200 pct all locations and 10.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
5.0 ac and 1.0 dc -
Switch Voltage Rating And Type In Volts
125.0 ac and 50.0 dc -
Frequency In Hertz
60.0 all locations -
Unpackaged Unit Weight
14.000 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5935-00-448-7205 MPN 177-10-02-47Electrical Receptacle Connector
- 5950-01-258-9718 MPN 179-47-00-29Reactor
- 5945-00-827-1722 MPN AN1-522XBX24VDCElectromagnetic Relay
- 5925-00-503-6469 MPN AM12MG3-20-125-4Circuit Breaker
- 5925-00-683-1440 MPN 3363-10-250AC2Circuit Breaker
- 5925-01-024-9567 MPN AM12MG6-3-208VAC400C14Circuit Breaker
- 5925-01-045-5146 MPN AM3-C2-A-12-5-2Circuit Breaker
- 5925-01-050-8195 MPN 70-639-2MG3Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-893-8383 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AM333HKMG6-2-250-4-60 | Eaton Corp |
148-85-5 | Litton Systems Inc |
AM333HKMG6-2-250VAC60C4 | Eaton Corp |
148-85-5 | Northrop Grumman Systems Corporation |