NSN 5925-00-950-6701
Overload Switch
Metal case material, 3 poles, 200.0 amperes ac all locations and 200.0 amperes dc all locations maximum continuous load current rating per pole, operating voltage type and rating per pole in volts: 600.0 ac all locations and 250.0 dc all locations.
Manufacturer part number AK2-50-1600A3P for national stock number 5925009506701.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-950-6701.
-
MPN or Model
AK2-50-1600A3P
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Case Material
Metal -
Unthreaded Mounting Hole Diameter
0.562 inches -
Pole Quantity
3 -
Mounting Facility Type And Quantity
2 unthreaded hole -
Features Provided
Adjustable trip release -
Maximum Continuous Load Current Rating Per Pole
200.0 amperes ac all locations and 200.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations and 250.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
42000.0 ac all locations and 42000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Internal Trip Release Configuration
Series trip all locations -
Trip Delay Time In Seconds Per Rated Continuous Current
5.000 at 200 pct all locations and 20.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Explosion proof -
Frequency In Hertz
60.0 all locations -
Terminal Type And Quantity
6 screw
More from these suppliers
- 5930-01-440-9413 MPN 080DPPPush Switch
- 5925-00-139-2681 MPN TED136015Circuit Breaker
- 5925-00-885-8378 MPN 343L695ETG4Circuit Breaker
- 5925-01-026-5114 MPN TEB122050WLCircuit Breaker
- 5925-01-137-5668 MPN TFK236200WLCircuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-950-6701 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AK2-50-1600A3P | General Electric Co |