NSN 5925-00-958-8215
Overload Switch
Multipole-multiple actuator type body style, plastic case material, 3 poles, arc quenching method: magnetic blowout.
Manufacturer part number SM-C-208902-1 for national stock number 5925009588215.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-958-8215.
-
MPN or Model
SM-C-208902-1
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-multiple actuator type -
Body Length
2.520 inches -
Body Width
2.280 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.200 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.810 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
Mounting Surface To Terminal End Distance
2.010 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
500.0 milliamperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
208.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Ultimate Trip Time Per Pole In Seconds
2.000 all locations and 10.000 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 at 200 pct all locations and 9.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant -
Frequency In Hertz
60.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 tab w/screw
More from these suppliers
- 5925-00-233-7523 MPN PAM333HEMG6-25-250-400Circuit Breaker
- 5925-00-408-8845 MPN GB3-A2A3A3-20-9-60Circuit Breaker
- 5925-00-763-8079 MPN AM333-5-47Circuit Breaker
- 5925-00-925-2164 MPN G330011S17Circuit Breaker
- 5925-01-013-8329 MPN HE2-C5-2-1Circuit Breaker
- 5925-01-032-3461 MPN AM12MG6-0.25-125-4-60Circuit Breaker
- 5925-01-275-6522 MPN AM1516MG3-50-28-2-DCCircuit Breaker
- 5925-01-321-1880 MPN 1135850G1Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-00-958-8215 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
SM-C-208902-1 | Us Army Communications & |
3XAM17-0.5-208-60 | Eaton Corp |