NSN 5925-00-978-4961
Overload Switch
Multipole-multiple actuator type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number 711570-224 for national stock number 5925009784961.
Datasheet
-
Product description
Circuit Breaker NSN 5925-00-978-4961.
-
MPN or Model
711570-224
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-multiple actuator type -
Body Length
Between 2.485 inches and 2.515 inches -
Body Width
Between 2.230 inches and 2.270 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.925 inches and 1.955 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.735 inches and 0.765 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.047 inches and 2.077 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.735 inches and 0.765 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.125 inches and 0.155 inches -
Mounting Surface To Terminal End Distance
Between 2.650 inches and 2.800 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
2.5 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole three -
Trip Delay Time In Seconds Per Rated Continuous Current
3.000 at 200 pct all locations and 10.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Salt spray proof and shock resistant and vibration resistant and moisture resistant -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
5.0 ac and 1.0 dc -
Switch Voltage Rating And Type In Volts
115.0 ac and 50.0 dc -
Frequency In Hertz
400.0 all locations -
Unpackaged Unit Weight
0.875 pounds -
Test Data Document
05869-711570 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing) -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5905-00-104-8334 MPN 4171300-39Composition Fixed Resistor
- 5935-00-110-0308 MPN 712230-233Electrical Receptacle Connector Body
- 5985-00-188-9665 MPN 723786-1Variable Attenuator
- 5905-00-195-6817 MPN 4171300-98Composition Fixed Resistor
- 5905-00-279-1682 MPN 4171302-111Composition Fixed Resistor
- 5905-00-279-3837 MPN 4171302-108Composition Fixed Resistor
- 5950-00-321-8213 MPN 722772-001Current Transformer
- 5950-00-538-3843 MPN 718899-042Reactor
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-00-978-4961 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
711570-224 | Raytheon Company |
72-125-50MG6 | Eaton Corp |