NSN 5925-01-035-3971
Overload Switch
Multipole-multiple actuator type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number AM3-A2-20-2 for national stock number 5925010353971.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-035-3971.
-
MPN or Model
AM3-A2-20-2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-multiple actuator type -
Body Length
Between 2.490 inches and 2.510 inches -
Body Width
Between 2.240 inches and 2.251 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.928 inches and 1.948 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.740 inches and 0.760 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.052 inches and 2.072 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.740 inches and 0.760 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.130 inches and 0.150 inches -
Mounting Surface To Terminal End Distance
Between 2.461 inches and 2.481 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole two -
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct all locations and 20.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
10.0 ac and 4.0 dc -
Switch Voltage Rating And Type In Volts
250.0 ac and 30.0 dc -
Frequency In Hertz
60.0 all locations -
Unpackaged Unit Weight
14.000 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
6 threaded stud
More from these suppliers
- 5925-00-014-6417 MPN AM333MG6-25-115AC400-15Circuit Breaker
- 5925-00-050-0414 MPN AM333MG6-50-250AC60-5Circuit Breaker
- 5925-00-259-5682 MPN JA2S-A3-A-20-PCircuit Breaker
- 5925-00-280-2273 MPN 2263Circuit Breaker
- 5925-00-655-3893 MPN 53-161MG3-5-416AC-1-400HZCircuit Breaker
- 5925-00-660-3892 MPN 3XAM1516MG3-40-416VAC11Circuit Breaker
- 5925-00-660-4206 MPN AM1516MG6-75-28VDC3Circuit Breaker
- 5925-00-812-2790 MPN AM12HKMG3-3-125-60-4Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-035-3971 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AM3-A2-20-2 | Eaton Corp |