NSN 5925-01-058-4970
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number 5388GX7 for national stock number 5925010584970.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-058-4970.
-
MPN or Model
5388GX7
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Body Style
Single pole type -
Overall Length
2.000 inches -
Body Width
1.188 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
0.906 inches -
Unthreaded Mounting Hole Diameter
0.250 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.574 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.234 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
2 unthreaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac single location and 15.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
110.0 ac single location and 30.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
600.0 ac single location and 600.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
130.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 push button -
Actuator Function
Reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Trip Delay Time In Seconds Per Rated Continuous Current
6.000 at 200 pct single location and 50.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Shockproof and vibrationproof -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location -
Frequency In Hertz
60.0 single location -
Unpackaged Unit Weight
0.062 pounds -
Terminal Type And Quantity
2 screw
More from these suppliers
- 5940-00-505-7704 MPN 2547HXConductor Splice
- 4820-01-226-5218 MPN 2CX296Directional Control Linear Valve
- 5935-01-524-7158 MPN 4KK779Electrical Receptacle Connector
- 5930-01-601-0996 MPN 3828484Toggle Switch
- 4820-00-278-6555 MPN 4WE6Hydraulic System Bleeder Valve
- 5940-01-462-1717 MPN 2186960Lug Terminal
- 4820-00-161-4095 MPN EE45435Metering Valve Assembly
- 5905-01-423-8059 MPN 2HS182Inductive Wire Wound Fixed Resistor
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-058-4970 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
5388GX7 | Oshkosh Corporation |
CM-15 | Sensata Technologies, Inc |
5388-G-7 | Oshkosh Corporation |
5388GX7 | Oshkosh Defense, Llc |
Stock Check