NSN 5925-01-062-4831
Overload Switch
Multipole-single actuator type body style, metal case material, moderately rugged fragility factor, pole quantity: 2.
Manufacturer part number 990C963H09 for national stock number 5925010624831.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-062-4831.
-
MPN or Model
990C963H09
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Bushing Length
Between 0.365 inches and 0.385 inches -
Body Length
Between 1.552 inches and 1.572 inches -
Body Width
Between 1.271 inches and 1.291 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
Between 0.865 inches and 0.885 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.615 inches and 0.635 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
Between 1.690 inches and 1.710 inches -
Pole Quantity
2 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
500.0 milliamperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
Between pole one and two -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.375 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.100 at 200 pct all locations and 0.500 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and hermetically sealed -
Frequency In Hertz
60.0 all locations -
Thread Series Designator
Unef -
Terminal Type And Quantity
4 wire hook
More from these suppliers
- 5985-00-251-1453 MPN 990C588H01Electrical Dummy Load
- 5985-01-310-7366 MPN 768R214G01Antenna
- 4920-01-423-0353 MPN AD420156G01Aircraft Components Test Set Subassembly
- 4920-01-370-4257 MPN 3D24810G01Test Adapter
- 5925-00-164-2965 MPN AM1516MG3-15-28-2DCCircuit Breaker
- 5925-00-174-3340 MPN P2263SM6-0-50Circuit Breaker
- 5925-00-238-6376 MPN 53-168-2MG3Circuit Breaker
- 5925-00-430-6342 MPN 72-218-2MG6Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-062-4831 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
990C963H09 | Northrop Grumman Systems Corporation |
AP12-1175-9 | Sensata Technologies Maryland, Inc |
SM33-0.6-60-2 | Eaton Corp |