NSN 5925-01-092-3417
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number 2TC14-4 for national stock number 5925010923417.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-092-3417.
-
MPN or Model
2TC14-4
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.1 lb -
Body Style
Single pole type -
Bushing Length
0.250 inches -
Body Length
1.781 inches -
Body Width
0.750 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
0.704 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
1.218 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
1 threaded bushing -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
4.0 amperes ac single location and 4.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac single location and 30.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 ac single location and 5000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Thermal single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 push-pull -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.469 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 at 200 pct single location and 20.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Corrosion resistant and vibration resistant and moisture resistant -
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location -
Frequency In Hertz
400.0 single location -
Unpackaged Unit Weight
62.0 grams -
Thread Series Designator
Uns -
Terminal Type And Quantity
2 tab w/screw
More from these suppliers
- 5905-00-023-8056 MPN 2211274G9Inductive Wire Wound Fixed Resistor
- 5940-00-237-8802 MPN 355098Terminal Board
- 5905-00-280-1273 MPN FRE24329-1Inductive Wire Wound Fixed Resistor
- 5950-00-335-6282 MPN 9010499Radio Frequency Coil
- 5905-00-909-5117 MPN 2064269-1Nonprecision Wire Wound Variable Resistor
- 5945-00-953-8834 MPN 2096273Motor Driven Relay
- 5905-00-993-9979 MPN 1064260Nonprecision Wire Wound Variable Resistor
- 4920-01-204-6285 MPN 2625983G003Electrical-electronic Equipment Test Station
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-092-3417 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
2TC14-4 | Sensata Technologies, Inc |
2137159G-4 | Harris Corporation |