NSN 5925-01-134-2746
Overload Switch
Inertial delay included.
Manufacturer part number UPL-1-1-61F-103 for national stock number 5925011342746.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-134-2746.
-
MPN or Model
UPL-1-1-61F-103
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Body Length
Between 2.480 inches and 2.500 inches -
Body Width
Between 0.740 inches and -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.925 inches and 1.955 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.050 inches and 2.070 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.130 inches and 0.150 inches -
Mounting Surface To Terminal End Distance
2.611 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.180 at 200 pct single location and 1.800 at 200 pct single location -
Inclosure Protection Type For Which Designed
Moisture resistant and salt spray proof and shock resistant and vibration resistant -
Frequency In Hertz
50.0 single location or 60.0 single location -
Unpackaged Unit Weight
3.700 ounces -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 threaded stud
More from these suppliers
- 5945-00-827-1722 MPN AN1-522XBX24VDC-10-SECElectromagnetic Relay
- 5925-00-471-2730 MPN SM3HK2DC1Circuit Breaker
- 5925-00-477-9644 MPN AM17-25-120-60-54Circuit Breaker
- 5925-00-553-9337 MPN XAM33MG3Circuit Breaker
- 5925-00-626-4343 MPN SM33-15-250VAC60C1Circuit Breaker
- 5925-00-686-0552 MPN 70-762-3 0AMPCircuit Breaker
- 5925-00-850-0469 MPN AM333HK-5-250-4-60Circuit Breaker
- 5925-00-949-0412 MPN 50-145-1MG3Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-134-2746 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
UPL-1-1-61F-103 | Sensata Technologies Maryland, Inc |
AM1-A8-A-10-30 | Eaton Corp |
Stock Check
![](/public/images/partscage_shelf3.png)