NSN 5925-01-137-3752
Overload Switch
Multipole-multiple actuator type body style, plastic case material, moderately rugged fragility factor, pole quantity: 2.
Manufacturer part number SM-A-973939-4 for national stock number 5925011373752.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-137-3752.
-
MPN or Model
SM-A-973939-4
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.5 lb -
Body Style
Multipole-multiple actuator type -
Body Length
2.500 inches -
Body Width
3.000 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.938 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
Fragility Factor
Moderately rugged -
Boss Height
0.140 inches -
Mounting Surface To Terminal End Distance
Between 2.409 inches and 2.533 inches -
Pole Quantity
2 -
Mounting Facility Type And Quantity
4 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
25.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Internal Trip Release Configuration
Series trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
10.500 at 200 pct first location and 60.000 at 200 pct first location -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Frequency In Hertz
50.0 all locations or 60.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
4 threaded stud
More from these suppliers
- 5925-00-175-9247 MPN 3363S-50A-208Circuit Breaker
- 5925-00-877-2862 MPN 53-119-3-MG3Circuit Breaker
- 5925-00-916-0367 MPN 3XAM17-15-115VAC400C56Circuit Breaker
- 5925-01-044-0306 MPN SM333HK5-50VDC2Circuit Breaker
- 5925-01-162-4002 MPN AM3-C2-0060-02ECircuit Breaker
- 5925-01-223-4801 MPN CD3Z248-2Circuit Breaker
- 5925-01-237-3886 MPN 3179574-27Circuit Breaker
- 5925-01-239-2040 MPN CE2-G3-U-30-120/240-1Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-137-3752 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
SM-A-973939-4 | Us Army Communications & |
APL11-7906-4 | Sensata Technologies Maryland, Inc |
AM2-Z325-1 | Eaton Corp |