NSN 5925-01-150-4559
Overload Switch
Multipole-multiple actuator type body style, plastic case material, 2 poles, storage type: general purpose warehouse.
Manufacturer part number 127-0352 for national stock number 5925011504559.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-150-4559.
-
MPN or Model
127-0352
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.4 lb -
Body Style
Multipole-multiple actuator type -
Body Length
2.000 inches -
Body Width
1.500 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.560 inches -
Center To Center Distance Between Terminals Parallel To Width
0.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
Boss Height
0.130 inches -
Mounting Surface To Terminal End Distance
2.210 inches -
Pole Quantity
2 -
Mounting Facility Type And Quantity
4 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
50.0 milliamperes dc first location -
Operating Voltage Type And Rating Per Pole In Volts
32.0 dc first location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc first location -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay second location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
2 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One and two linked -
Internal Trip Release Configuration
Series trip w/auxiliary load terminal second location -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
0.150 at 200 pct second location and 1.800 at 200 pct second location -
Inclosure Protection Type For Which Designed
Moisture resistant -
Frequency In Hertz
50.0 second location or 60.0 second location -
Thread Series Designator
Unc -
Terminal Type And Quantity
7 quick disconnect, male
More from these suppliers
- 5930-01-408-3554 MPN JA2-A0-APush Switch
- 5925-00-166-6779 MPN AM1-B3-2-65DCC-3Circuit Breaker
- 5925-00-308-7168 MPN 70-342-5Circuit Breaker
- 5925-00-449-0047 MPN AM12MG3-25-32DC5Circuit Breaker
- 5925-00-450-5189 MPN AM-12-311-1MG6Circuit Breaker
- 5925-00-460-5711 MPN CJ3-G3-U-200-9Circuit Breaker
- 5925-00-529-0441 MPN HR1Z1-117Circuit Breaker
- 5925-00-549-6803 MPN AM1615M6-70-28-1Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-150-4559 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
127-0352 | Kepco, Inc. |
127-0352 | Patterson Cooney, Inc. |
127-0352 | Eaton Corp |
Stock Check
![](/public/images/partscage_shelf3.png)