NSN 5925-01-242-2688
Overload Switch
Multipole-multiple actuator type body style, plastic case material, 3 poles, arc quenching method: magnetic blowout.
Manufacturer part number X-796-2 for national stock number 5925012422688.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-242-2688.
-
MPN or Model
X-796-2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
2.3 lb -
Body Style
Multipole-multiple actuator type -
Body Length
4.750 inches -
Body Width
3.108 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
3.550 inches -
Center To Center Distance Between Terminals Parallel To Width
1.026 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.750 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.026 inches -
Boss Height
0.220 inches -
Mounting Surface To Terminal End Distance
3.375 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole -
Storage Type
General purpose warehouse -
Features Provided
High inrush protection -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
4.5 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Internal Trip Release Configuration
Relay trip all locations -
Thread Size
0.138 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
40.000 at 200 pct all locations and 200.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Fungus resistant -
Frequency In Hertz
50.0 all locations or 60.0 all locations -
Unpackaged Unit Weight
2.000 pounds -
Thread Series Designator
Unc -
Terminal Type And Quantity
12 threaded stud
More from these suppliers
- 5925-00-008-4398 MPN AP1-1-7-2F153Circuit Breaker
- 5925-00-723-6148 MPN AP1-59ACircuit Breaker
- 5925-00-755-5319 MPN 501A152Circuit Breaker
- 5925-01-024-9568 MPN APL-1-1-62-302-MCircuit Breaker
- 5925-01-028-6504 MPN AP12-1-6-2-302Circuit Breaker
- 5925-01-054-3782 MPN APL11-4613-10Circuit Breaker
- 5925-01-076-4458 MPN AP1-4613-14Circuit Breaker
- 5925-01-112-4234 MPN AP1167064-249Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-242-2688 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
X-796-2 | Kohler Co. |
X-796-2 | Kohler Co Engine Plant Div |
219-3-4884-2 | Sensata Technologies Maryland, Inc |
219-3-4-66-3-8-4.5 | Sensata Technologies Maryland, Inc |