NSN 5925-01-247-5309
Overload Switch
Single pole type body style, 1 poles, 30.0 amperes ac single location maximum continuous load current rating per pole, operating voltage type and rating per pole in volts: 250.0 ac single location.
Manufacturer part number IPG-6-1-65F-303-C-00 for national stock number 5925012475309.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-247-5309.
-
MPN or Model
IPG-6-1-65F-303-C-00
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Body Style
Single pole type -
Body Length
2.000 inches -
Body Width
0.750 inches -
Center To Center Distance Between Terminals Parallel To Length
1.530 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches -
Pole Quantity
1 -
Mounting Facility Type And Quantity
2 threaded hole -
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Characteristic
Time delay single location -
Reset Method
Manual -
Internal Trip Release Configuration
Series trip single location -
Frequency In Hertz
400.0 single location
More from these suppliers
- 5925-00-164-2071 MPN APL11-1-62-203-MCircuit Breaker
- 5925-00-192-0767 MPN AP12-573-4Circuit Breaker
- 5925-00-306-2821 MPN APG-6-55629/7-022Circuit Breaker
- 5925-00-306-2827 MPN APL111-1-43-302-MCircuit Breaker
- 5925-00-967-6199 MPN AP1-1-5-0-302Circuit Breaker
- 5925-01-037-6894 MPN AP-1-1-62-501Circuit Breaker
- 5925-01-075-3807 MPN AP12-1R4-1-202Circuit Breaker
- 5925-01-141-6683 MPN AP-12-1R-62F-1751Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-247-5309 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
IPG-6-1-65F-303-C-00 | Sensata Technologies Maryland, Inc |