NSN 5925-01-250-4741
Overload Switch
Single pole type body style, metal case material, at 12 oclock nonturn device location, fragility factor: moderately rugged.
Manufacturer part number APGN-6-1-62-203 for national stock number 5925012504741.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-250-4741.
-
MPN or Model
APGN-6-1-62-203
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.3 lb -
Thread Pitch Diameters
+0.4752/+0.4787 inches -
Body Style
Single pole type -
Bushing Length
0.625 inches -
Body Length
2.000 inches -
Body Width
0.750 inches -
Case Material
Metal -
Center To Center Distance Between Terminals Parallel To Length
1.530 inches -
Nonturn Device Location
At 12 oclock -
Nonturn Device Radius
0.656 inches -
Nonturn Device Length
0.130 inches -
Nonturn Device Diameter
Between 0.151 inches and 0.161 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
2.232 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing w/panel seal -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
3500.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.500 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct single location and 20.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Hermetically sealed and shock resistant and vibration resistant -
Frequency In Hertz
50.0 single location or 60.0 single location -
Unpackaged Unit Weight
3.000 ounces -
Thread Series Designator
Un -
Terminal Type And Quantity
2 tab w/screw
More from these suppliers
- 5925-00-308-7168 MPN APL1R1195-5Circuit Breaker
- 5925-00-487-6527 MPN APL11141-203MCircuit Breaker
- 5925-00-952-5586 MPN 501B152Circuit Breaker
- 5925-01-020-3278 MPN UPL-1-1-62-202Circuit Breaker
- 5925-01-024-9568 MPN APL-1-1-62-302-MCircuit Breaker
- 5925-01-083-3041 MPN AP1-1R-4927-1Circuit Breaker
- 5925-01-112-0320 MPN AP112-1R7-2F1752Circuit Breaker
- 5925-01-148-1959 MPN 909800-6-1Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-250-4741 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
APGN-6-1-62-203 | Sensata Technologies Maryland, Inc |