NSN 5925-01-457-4638
Overload Switch
2 poles, 1.0 amperes ac all locations maximum continuous load current rating per pole, 277.0 ac all locations operating voltage type and rating per pole in volts, trip release method: magnetic all locations.
Manufacturer part number 205-11-1-REC5-65-5-102-A for national stock number 5925014574638.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-457-4638.
-
MPN or Model
205-11-1-REC5-65-5-102-A
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Body Length
2.490 inches -
Body Width
1.515 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches -
Pole Quantity
2 -
Mounting Facility Type And Quantity
4 unthreaded hole -
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
277.0 ac all locations -
Trip Release Method
Magnetic all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Electric -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Internal Trip Release Configuration
Series trip w/auxiliary load terminal all locations -
Inclosure Protection Type For Which Designed
Dustproof -
Frequency In Hertz
50.0 all locations or 60.0 all locations -
Terminal Type And Quantity
4 threaded stud
More from these suppliers
- 5925-01-041-3866 MPN 501A402Circuit Breaker
- 5925-01-112-0320 MPN AP-112-1R-52F-1752Circuit Breaker
- 5925-01-141-6683 MPN AP-12-1R-62F-1751Circuit Breaker
- 5925-01-160-7609 MPN AP112-8475-1Circuit Breaker
- 5925-01-177-1073 MPN APL111-1REC1-62-303Circuit Breaker
- 5925-01-179-4774 MPN APL-111-1RO-62F-253Circuit Breaker
- 5925-01-242-9943 MPN 205-111-1-65-5A-203Circuit Breaker
- 5925-01-242-9944 MPN AP-16-1-71-202Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-457-4638 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
205-11-1-REC5-65-5-102-A | Sensata Technologies Maryland, Inc |