Overload Switch
1 poles, 20.0 amperes dc single location maximum continuous load current rating per pole, 50.0 dc single location operating voltage type and rating per pole in volts, trip release method: magnetic single location.
Manufacturer part number APL2-9433-1 for national stock number 5925012553079.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-255-3079.
-
MPN or Model
APL2-9433-1
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Pole Quantity
1 -
Maximum Continuous Load Current Rating Per Pole
20.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Main Contact Tripping Mechanism Type
Trip free -
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 at 125 pct single location and 6.500 at 125 pct single location and 0.300 at 150 pct single location and 3.000 at 150 pct single location and 0.130 at 200 pct single location and 1.200 at 200 pct single location and 0.031 at 400 pct single location and 0.220 at 400 pct single location and 0.031 at 600 pct single location and 0.220 at 600 pct single location and 0.0110 at 800 pct single location and 0.110 at 800 pct single location and 0.004 at 1000 pct single location and 0.050 at 1000 pct single location
More from these suppliers
- 5985-00-253-4296 MPN 004082Directional Coupler
- 4920-00-772-2426 MPN TX12650Ball Extractor Seat
- 5975-01-633-1608 MPN CB43833-001Electrical Equipment Drawer
- 5985-01-462-5976 MPN 710771-100Radome
- 5905-01-580-0565 MPN CA64269-002Thermal Resistor
- 5930-01-227-4900 MPN 920241-100Pressure Switch
- 5985-01-462-5997 MPN 710500-100Antenna Support
- 5925-00-919-1771 MPN APL1R571-010Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-255-3079 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
APL2-9433-1 | Sensata Technologies Maryland, Inc |
911383-001 | Moog Inc. |
Stock Check
![](/public/images/partscage_shelf3.png)