NSN 5925-01-295-9063
Overload Switch
Multipole-multiple actuator type body style, plastic case material, 3 poles, maximum continuous load current rating per pole: 10.0 amperes ac all locations.
Manufacturer part number AM3S-A2A3A3-L-A-07-D-A-52-10-2 for national stock number 5925012959063.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-295-9063.
-
MPN or Model
AM3S-A2A3A3-L-A-07-D-A-52-10-2
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
Body Style
Multipole-multiple actuator type -
Body Length
2.500 inches -
Body Width
2.250 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.938 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.062 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.500 inches -
Boss Height
0.140 inches -
Mounting Surface To Terminal End Distance
2.091 inches -
Pole Quantity
3 -
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Characteristic
Time delay all locations -
Inclosure Protection Type For Which Designed
Fungus resistant and moisture resistant -
Frequency In Hertz
60.0 all locations
More from these suppliers
- 5925-00-038-5894 MPN AM1-Z22-080Circuit Breaker
- 5925-00-052-1743 MPN 74-106-4Circuit Breaker
- 5925-00-137-0688 MPN 3XAM1516MG3-20-250-2-400Circuit Breaker
- 5925-00-270-4002 MPN AM13-10-125-400Circuit Breaker
- 5925-00-581-3889 MPN 3363SMG4-30-250CURVE3Circuit Breaker
- 5925-00-660-3892 MPN 33-119-4-MG3Circuit Breaker
- 5925-00-890-8748 MPN AM12MG3Circuit Breaker
- 5925-00-937-9572 MPN SM33-12-50VDC2Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-295-9063 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
AM3S-A2A3A3-L-A-07-D-A-52-10-2 | Eaton Corp |