NSN 5925-01-297-8574
Overload Switch
Single pole type body style, plastic case material, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number T11-3-3.00A-01-31-V for national stock number 5925012978574.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-297-8574.
-
MPN or Model
T11-3-3.00A-01-31-V
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Bushing Length
Between 0.458 inches and 0.478 inches -
Body Length
Between 1.365 inches and 1.385 inches -
Body Width
Between 0.670 inches and 0.690 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.095 inches and 1.155 inches -
Fragility Factor
Moderately rugged -
Mounting Surface To Terminal End Distance
Between 1.525 inches and 1.585 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
1 threaded bushing -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac single location and 3.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location and 50.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location and 1000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.500 inches -
Trip Delay Time In Seconds Per Rated Continuous Current
1.000 at 200 pct single location and 15.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Dustproof -
Frequency In Hertz
50.0 single location or 60.0 single location -
Thread Series Designator
Un -
Terminal Type And Quantity
2 tab, solder lug
More from these suppliers
- 5945-00-553-9611 MPN C300Electronic Chopper
- 5930-01-155-9287 MPN UPL1-0-00-000Toggle Switch
- 5925-00-226-1155 MPN 501I102Circuit Breaker
- 5925-00-308-7193 MPN APL11-1-61-302Circuit Breaker
- 5925-01-020-7706 MPN APL-11-1RE-42-252-MACircuit Breaker
- 5925-01-044-8589 MPN 203-2-2-62-502-4-1-1Circuit Breaker
- 5925-01-064-7821 MPN UPL1-3327-238Circuit Breaker
- 5925-01-114-3429 MPN UPL1111-5242-6Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-297-8574 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
T11-3-3.00A-01-31-V | Sensata Technologies Maryland, Inc |
T11-3-3.00A-01-31 | Sensata Technologies Maryland, Inc |