NSN 5925-01-302-3307
Overload Switch
Rectangular dimensional envelope body style, plastic case material, moderately rugged fragility factor, pole quantity: 3.
Manufacturer part number ETN-3599 for national stock number 5925013023307.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-302-3307.
-
MPN or Model
ETN-3599
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Rectangular dimensional envelope -
Overall Length
22.000 inches -
Overall Height
7.438 inches -
Overall Width
9.000 inches -
Case Material
Plastic -
Fragility Factor
Moderately rugged -
Pole Quantity
3 -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Maximum Continuous Load Current Rating Per Pole
800.0 amperes ac all locations and 800.0 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
500.0 ac all locations and 250.0 dc all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
50000.0 ac all locations and 5000.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Characteristic
Instantaneous all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Inclosure Protection Type For Which Designed
General purpose -
Frequency In Hertz
60.0 all locations
More from these suppliers
- 5985-00-581-9650 MPN 497406-902Radio Frequency Transmission Line Section
- 5930-00-646-9156 MPN 701348PC701348-6Rotary Switch
- 5930-01-358-7648 MPN 33-43002-B-01PC300Rotary Switch
- 5930-01-380-9899 MPN 740102PC37Push Switch
- 5930-01-432-0963 MPN 8-42-10Electrical Switch Retainer
- 5975-01-604-8304 MPN 120808-A00Lug Boot
- 5940-01-359-4797 MPN 33-43002-B-01PC251ALug Terminal
- 5950-00-518-2808 MPN 175351PC1122Electrical Coil
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-302-3307 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
ETN-3599 | Spd Electrical Systems, Inc |
ETN8269 | Spd Electrical Systems, Inc |
ETN8266 | Spd Electrical Systems, Inc |