NSN 5925-01-312-7534
Overload Switch
Single pole type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number 16781037-004 for national stock number 5925013127534.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-312-7534.
-
MPN or Model
16781037-004
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Body Length
Between 1.985 inches and 2.015 inches -
Body Width
Between 0.740 inches and 0.760 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.560 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 1.650 inches and 1.670 inches -
Switch Contact Arrangement
Single pole, double throw -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.120 inches and 0.140 inches -
Mounting Surface To Terminal End Distance
2.210 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Features Provided
High inrush protection -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
25.0 amperes dc single location -
Operating Voltage Type And Rating Per Pole In Volts
65.0 dc single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2000.0 dc single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Switch Location And Position Designation
External at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
0.600 at 200 pct single location and 9.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Dustproof -
Switch Terminal Type
Tab, solder lug -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 tab, solder lug
More from these suppliers
- 5945-00-419-6703 MPN BN4-522XAX115VAC60HZ2SECElectromagnetic Relay
- 5925-00-271-2665 MPN AM1-Z21-015Circuit Breaker
- 5925-00-482-5779 MPN JA2Z21-3M0DIFIEDCircuit Breaker
- 5925-00-581-3888 MPN 3363SMG4-25-120CURVE2Circuit Breaker
- 5925-00-763-8078 MPN AM333-5-25Circuit Breaker
- 5925-01-024-9567 MPN AM12MG6-3-208VAC400C14Circuit Breaker
- 5925-01-137-2234 MPN G396183AF250A50Circuit Breaker
- 5925-01-152-1188 MPN CD3-A2A3A3-5-480-3Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-312-7534 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
16781037-004 | Sypris Electronics, Llc |
16781037-004 | Sensata Technologies Maryland, Inc |
16781037-004 | Eaton Corp |
JA1S-B3-A-25-2 | Eaton Corp |