NSN 5925-01-330-2360
Overload Switch
Multipole-multiple actuator type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number 2613582-1 for national stock number 5925013302360.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-330-2360.
-
MPN or Model
2613582-1
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Unit Weight (Est.)
0.9 lb -
Thread Pitch Diameters
+0.1177/+0.1214 inches -
Body Style
Multipole-multiple actuator type -
Body Length
Between 3.970 inches and 4.010 inches -
Body Width
2.265 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
Between 1.925 inches and 1.955 inches -
Center To Center Distance Between Terminals Parallel To Width
Between 0.735 inches and 0.765 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
Between 2.050 inches and 2.070 inches -
Switch Contact Arrangement
Single pole, double throw -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
Between 0.735 inches and 0.765 inches -
Fragility Factor
Moderately rugged -
Boss Height
Between 0.135 inches and 0.165 inches -
Mounting Surface To Terminal End Distance
Between 2.594 inches and 2.656 inches -
Pole Quantity
3 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
6 threaded hole -
Storage Type
General purpose warehouse -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
30.0 amperes ac all locations -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1500.0 ac all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic all locations -
Auxiliary Trip Coil Voltage Type And Rating In Volts
100.0 ac first location -
Trip Release Characteristic
Time delay all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
3 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At each pole -
External Actuator Linkage Arrangement
One, two, and three linked -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series/relay trip first location -
Thread Size
0.138 inches -
Trip Release Duty Cycle
Continuous first location -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct all locations and 22.000 at 200 pct all locations -
Inclosure Protection Type For Which Designed
Dustproof and fungus proof -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
10.0 ac and 10.0 dc -
Switch Voltage Rating And Type In Volts
250.0 ac and 65.0 dc -
Frequency In Hertz
400.0 all locations -
Thread Series Designator
Unc -
Terminal Type And Quantity
8 threaded stud
More from these suppliers
- 5905-00-415-4330 MPN 2606561Precision Wire Wound Variable Resistor
- 5905-01-200-7728 MPN 2612763-1Film Fixed Resistor Network
- 5925-00-045-8091 MPN 520A402Circuit Breaker
- 5925-00-313-6049 MPN AP12-1R2107-1Circuit Breaker
- 5925-00-488-2740 MPN APL111-1-41-202Circuit Breaker
- 5925-01-023-1410 MPN AP1-1-6-0-103Circuit Breaker
- 5925-01-063-7107 MPN 299-4-4900-1Circuit Breaker
- 5925-01-145-5328 MPN APL1113-ER6864Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
![Mechanic Bill explains Overload Switch](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 5925-01-330-2360 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
2613582-1 | Alliant Techsystems Operations Llc |
APL112-1RO-22787-1 | Sensata Technologies Maryland, Inc |