NSN 5925-01-339-6540
Overload Switch
Plastic case material, single pole, double throw switch contact arrangement, moderately rugged fragility factor, pole quantity: 1.
Manufacturer part number UPG-6-1REC5-62-153-01 for national stock number 5925013396540.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-339-6540.
-
MPN or Model
UPG-6-1REC5-62-153-01
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Length
2.000 inches -
Body Width
0.750 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.530 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches -
Switch Contact Arrangement
Single pole, double throw -
Fragility Factor
Moderately rugged -
Boss Height
0.130 inches -
Mounting Surface To Terminal End Distance
2.032 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Thready Qty Per Inch (tpi)
32 -
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct single location and 20.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
Dustproof and fungus proof -
Switch Terminal Type
Tab, solder lug -
Switch Current Rating And Type In Amps
10.0 ac and 3.0 dc -
Switch Voltage Rating And Type In Volts
250.0 ac and 50.0 dc -
Frequency In Hertz
50.0 single location or 60.0 single location -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 tab w/screw
More from these suppliers
- 5925-00-005-8912 MPN APG-111-1-42-751-00Circuit Breaker
- 5925-00-308-7196 MPN APL-1-1-42-153-MCircuit Breaker
- 5925-00-317-9985 MPN APL11-1-51-153-MCircuit Breaker
- 5925-00-323-9910 MPN APL1-55629-1-118Circuit Breaker
- 5925-01-037-5866 MPN 39019-3-51Circuit Breaker
- 5925-01-038-1352 MPN AP1-76-18Circuit Breaker
- 5925-01-042-8668 MPN AP12-1R6-2-202Circuit Breaker
- 5925-01-054-5473 MPN AP12-3-4-1-153Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-339-6540 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
UPG-6-1REC5-62-153-01 | Sensata Technologies Maryland, Inc |