NSN 5925-01-567-9123

Overload Switch

About this product

Screw terminals are bent in 30 degrees; screws are 0.313 in. Long and are no. 10-30 with captive washers.

Manufacturer part number IUGN66-33968-5 for national stock number 5925015679123.

Datasheet

  • Product description

    Circuit Breaker NSN 5925-01-567-9123.

  • MPN or Model

    IUGN66-33968-5

  • Schedule B
    8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi)
  • NMF (National Motor Freight)
    061300 - Circuit Breaker/switch NOI
  • Body Style
    Multipole-multiple actuator type
  • Bushing Length
    0.240 inches
  • Body Length
    2.000 inches
  • Body Width
    1.515 inches
  • Case Material
    Metal
  • Center To Center Distance Between Terminals Parallel To Length
    1.530 inches
  • Center To Center Distance Between Terminals Parallel To Width
    0.750 inches
  • Unthreaded Mounting Hole Diameter
    0.156 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
    1.660 inches
  • Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
    0.750 inches
  • End Application
    Boat, patrol, 34 foot, 34pb0601 through 34pb0609 and 34pb0701
  • Mounting Surface To Terminal End Distance
    2.075 inches
  • Pole Quantity
    2
  • Mounting Facility Type And Quantity
    4 unthreaded hole
  • Maximum Continuous Load Current Rating Per Pole
    5.0 amperes ac all locations and 5.0 amperes dc all locations
  • Operating Voltage Type And Rating Per Pole In Volts
    240.0 ac all locations and 80.0 dc all locations
  • Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
    5000.0 ac all locations and 7500.0 dc all locations
  • Circuit Protection Type
    Overcurrent all locations
  • Trip Release Method
    Magnetic all locations
  • Trip Release Characteristic
    Time delay all locations
  • Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
    1000.0 all locations
  • Reset Method
    Manual
  • Main Contact Tripping Mechanism Type
    Trip free
  • Manual Actuator Type And Quantity
    1 toggle
  • Actuator Position Designation
    At pole one
  • Internal Trip Release Configuration
    Series trip all locations
  • Trip Delay Time In Seconds Per Rated Continuous Current
    1.000 at 200 pct all locations and 20.000 at 200 pct all locations
  • Part Name Assigned By Controlling Agency
    Cage: iug magnetic circuit protector
  • Frequency In Hertz
    60.0 all locations
  • Terminal Type And Quantity
    4 screw
Circuit Breaker

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.

Mechanic Bill explains Overload Switch

Pricing and Availability

Get a quote for 5925-01-567-9123 circuit breaker
Quantity:
Your Email:
Your Name:
Company Name:
Optional reference:
Phone:
NSN 5925015679123

We do not share, sell, or distribute your information to any third party.
Privacy | Terms

All major credit cards accepted as well as gov. p-cards
Manufacturer Part Numbers and Alternates
MPN manufacturer part number Registrant or Supplier
IUGN66-33968-5 Sensata Technologies Maryland, Inc
Stock Check