Overload Switch
This unit has a sealed toggle. The operating temp range is minus 40 degrees to plus 85 degrees celcius..
Manufacturer part number IUGN66-1-51-7.50 for national stock number 5925016068674.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-606-8674.
-
MPN or Model
IUGN66-1-51-7.50
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Multipole-single actuator type -
Body Length
2.0 inches -
Body Width
1.515 inches -
Body Height
2.256 inches -
Center To Center Distance Between Terminals Parallel To Length
1.53 inches -
End Application
Boat, diver s -
Pole Quantity
2 -
Maximum Continuous Load Current Rating Per Pole
7.5 amperes dc all locations -
Operating Voltage Type And Rating Per Pole In Volts
80.0 dc all locations -
Circuit Protection Type
Overcurrent all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 all locations -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Internal Trip Release Configuration
Series trip all locations -
Terminal Type And Quantity
4 screw
More from these suppliers
- 5925-00-135-6136 MPN AP1R2AMPD1Circuit Breaker
- 5925-00-306-2826 MPN APL1-1R0-61-302-MCircuit Breaker
- 5925-01-030-2963 MPN UPG1-1957-11Circuit Breaker
- 5925-01-044-0309 MPN AP-MIL-1-7-2-103Circuit Breaker
- 5925-01-064-4094 MPN APL-11111-4809-1Circuit Breaker
- 5925-01-069-7607 MPN 203-11-2236-14Circuit Breaker
- 5925-01-120-9107 MPN APL-111-5490-1Circuit Breaker
- 5925-01-133-9487 MPN 299-3-4166-040Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-606-8674 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
IUGN66-1-51-7.50 | Sensata Technologies Maryland, Inc |