NSN 5925-01-608-5259
Overload Switch
Dc 50/60hz; push to reset: no button markings.
Manufacturer part number PR11-1-20.0A-XX for national stock number 5925016085259.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-608-5259.
-
MPN or Model
PR11-1-20.0A-XX
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Overall Length
Between 1.365 inches and 1.385 inches -
Overall Width
Between 0.670 inches and 0.690 inches -
Center To Center Distance Between Terminals Parallel To Length
Between 1.095 inches and 1.155 inches -
End Application
5865-01-592-7907 -
Boss Height
Between 0.458 inches and 0.478 inches -
Mounting Surface To Terminal End Distance
Between 1.685 inches and 1.745 inches -
Pole Quantity
1 -
Maximum Continuous Load Current Rating Per Pole
20.0 amperes dc all locations -
Trip Release Method
Magnetic-hydraulic all locations -
Reset Method
Manual -
Internal Trip Release Configuration
Series trip all locations -
Part Name Assigned By Controlling Agency
Hydraulic magnetic circuit protector (snapak); circuit breaker
More from these suppliers
- 5930-01-567-1042 MPN AP17-164-203Toggle Switch
- 5925-00-426-9063 MPN AP-1-1R-50-102Circuit Breaker
- 5925-01-031-9915 MPN AP1-785-1Circuit Breaker
- 5925-01-113-6827 MPN AP112-7499-2Circuit Breaker
- 5925-01-169-0995 MPN AP16-1RC-5950-003Circuit Breaker
- 5925-01-246-4518 MPN 209-3-1-63F-4-2-10Circuit Breaker
- 5925-01-293-7342 MPN APL11-1R01-5-1-103Circuit Breaker
- 5925-01-295-0434 MPN 203-1-1-61-102-1-1Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-608-5259 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
PR11-1-20.0A-XX | Sensata Technologies Maryland, Inc |
PR11-1-20.0A-XX | Sensata Technologies Maryland, Inc |