NSN 6145-00-810-7585
Electric Cable
Round cross sectional shape, 0.200 inches cross section outside diameter, 2 conductors, strand quantity per conductor: 7 all conductors.
Manufacturer part number 18-2BNSJ7T for national stock number 6145008107585.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-00-810-7585.
-
MPN or Model
18-2BNSJ7T
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Unit Weight (Est.)
0.4 lb -
Cross Sectional Shape
Round -
Cross Section Outside Diameter
0.200 inches -
Conductor Quantity
2 -
Strand Quantity Per Conductor
7 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
18 awg all conductors -
Strand Awg Size Per Conductor
26 all conductors -
Conductor Arrangement And Quantity
2 singles -
Voltage Rating
600.0 ac rated working voltage all conductors -
Material
Tin 2nd position coating cable -
Surface Treatment
Tin core conductor all conductors -
Nondefinitive Specification/std Data
1 type and 1 style
More from these suppliers
- 5905-00-001-5665 MPN MILR22-12Nonprecision Wire Wound Variable Resistor
- 5905-00-004-0189 MPN RBR56L57401BRNoninductive Wire Wound Fixed Resistor
- 5905-00-004-6095 MPN MILR55182-3Film Fixed Resistor
- 5905-00-005-2670 MPN RBR71L58510BRNoninductive Wire Wound Fixed Resistor
- 5935-00-005-8857 MPN MILC83723-86Electrical Plug Connector
- 5905-00-006-7040 MPN RNR60C3612DSFilm Fixed Resistor
- 5935-00-009-2924 MPN MIL-DTL-83723/73Electrical Receptacle Connector
- 5905-00-009-6477 MPN RNR55C5110DSFilm Fixed Resistor
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
Pricing and Availability
Get a quote for 6145-00-810-7585 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
18-2BNSJ7T | Cities Service Co Chester Cable |
MILC27072 | Military Specifications |