NSN 6145-01-390-6466
Electric Cable
Round cross sectional shape, -20.0 degrees celsius and 60.0 degrees celsius tempurature rating, 0.575 inches cross section outside diameter, conductor quantity: 2.
Manufacturer part number UL62 for national stock number 6145013906466.
Datasheet
-
Product description
Electrical Power Cable NSN 6145-01-390-6466.
-
MPN or Model
UL62
-
Schedule B
8544.60.6000 (Insulated electric conductors for a voltage exceeding 1000 v, nesoi) -
NMF (National Motor Freight)
030310 - Cable Or Wire -
Cross Sectional Shape
Round -
Tempurature Rating
-20.0 degrees celsius and 60.0 degrees celsius -
Cross Section Outside Diameter
0.575 inches -
Conductor Quantity
2 -
Strand Quantity Per Conductor
65 all conductors -
Conductor Form
Stranded all conductors -
Round Conductor Size
12 awg all conductors -
Strand Awg Size Per Conductor
30 all conductors -
Conductor Arrangement And Quantity
2 singles -
Voltage Rating
600.0 root mean square (rms) operating voltage all conductors -
Color
Yellow 2nd position jacket cable -
Material
Plastic polyvinyl chloride 2nd position jacket cable -
Material Specification
Astm b174 assn standard single material response core conductor all conductors
More from these suppliers
- 6145-01-390-6466 MPN 86692Electrical Power Cable
- 5975-00-518-1726 MPN WJ800Junction Box
- 5975-00-548-8776 MPN WJ800Junction Box
- 5975-00-644-3173 MPN W-C-586Conduit Outlet
- 5930-01-087-2674 MPN LDCL2DN2SNBX3R100A240VBox Switch
- 5935-01-209-1838 MPN WC596-6Electrical Receptacle Connector
- 5930-00-082-0441 MPN WS865Box Switch
- 5975-01-032-4636 MPN WW-C-581Rigid Metal Conduit
Two or more insulated conductors (solid or stranded) contained in a common covering, or two or more insulated conductors twisted or molded together without a common covering, or one insulated conductor with a metallic covering, covering, shield, or outer conductor. The rated working voltage of the item must be 300 volts or more, or in lieu of this the test voltage must be 1,000 volts or more; and the size of each individual conductor must be number 18 american wire gage (0.75 square millimeters) or larger. For cables with uninsulated neutral conductor use the hightest rated voltage. Refers to bulk quantities only, for items of definite length with processed ends or terminated in fittings, see cable assembly, power, electrical. For low voltage aircraft and automotive cable, see cable, special purpose, electrical.
![Mechanic Bill explains Electric Cable](/public/images/billy-thinking.png)
Pricing and Availability
Get a quote for 6145-01-390-6466 electrical power cableManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
UL62 | Underwriters Laboratories Inc. |
STO#12-2 | Kendall Electric Inc |
UL62STO6CK2/12TPETPE | Underwriters Laboratories Inc. |
86692 | Manatee, County Of |
J-C-580 | Federal Specifications |
J-C-580STO6CK2/12TTJ | Federal Specifications |
W5052 | York Technical Institute Llc |
Stock Check
![](/public/images/partscage_shelf3.png)