Overload Switch
Single pole type body style, plastic case material, single pole, double throw switch contact arrangement, fragility factor: moderately rugged.
Manufacturer part number UPG-1-1REC2-62F-502-90 for national stock number 5925012070910.
Datasheet
-
Product description
Circuit Breaker NSN 5925-01-207-0910.
-
MPN or Model
UPG-1-1REC2-62F-502-90
-
Schedule B
8536.20.0040 (Automatic circuit breakers, for a voltage not exceeding 1, 000 v, nesoi) -
NMF (National Motor Freight)
061300 - Circuit Breaker/switch NOI -
Body Style
Single pole type -
Body Length
2.000 inches -
Body Width
0.750 inches -
Case Material
Plastic -
Center To Center Distance Between Terminals Parallel To Length
1.530 inches -
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.660 inches -
Switch Contact Arrangement
Single pole, double throw -
Fragility Factor
Moderately rugged -
Boss Height
0.130 inches -
Mounting Surface To Terminal End Distance
2.000 inches -
Pole Quantity
1 -
Arc Quenching Method
Magnetic blowout -
Mounting Facility Type And Quantity
2 threaded hole -
Storage Type
General purpose warehouse -
Special Handling Feature
Magnetic -
Features Provided
High inrush protection -
Maximum Continuous Load Current Rating Per Pole
5.0 amperes ac single location -
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location -
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
5000.0 ac single location -
Circuit Protection Type
Overcurrent single location -
Trip Release Method
Magnetic-hydraulic single location -
Trip Release Characteristic
Time delay single location -
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location -
Reset Method
Manual -
Main Contact Tripping Mechanism Type
Trip free -
Manual Actuator Type And Quantity
1 toggle -
Actuator Function
Trip-reset -
Actuator Position Designation
At pole one -
Auxiliary Switch Function And Quantity
1 alarm -
Internal Trip Release Configuration
Series trip single location -
Thread Size
0.138 inches -
Switch Location And Position Designation
Internal at pole one -
Trip Delay Time In Seconds Per Rated Continuous Current
2.250 at 200 pct single location and 11.000 at 200 pct single location -
Inclosure Protection Type For Which Designed
General purpose -
Switch Terminal Type
Quick disconnect, male -
Frequency In Hertz
50.0 single location or 60.0 single location -
Thread Series Designator
Unc -
Terminal Type And Quantity
2 quick disconnect, male
More from these suppliers
- 5925-00-067-3359 MPN 3XAM17-20-208AC56-400HZCircuit Breaker
- 5925-00-529-0441 MPN HE1B3-12-5-2Circuit Breaker
- 5925-00-544-5314 MPN AM333MG6-50-250VAC400-16Circuit Breaker
- 5925-00-553-2272 MPN 343363SCircuit Breaker
- 5925-00-660-3892 MPN 33-119-4-MG3Circuit Breaker
- 5925-00-910-3594 MPN AM1B2-1-12VDCPCircuit Breaker
- 5925-00-979-9072 MPN 79-102-13-1-75-230-400-2Circuit Breaker
- 5925-01-005-9799 MPN AM12-5-120-60-4Circuit Breaker
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating element(s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified); and controller.
Pricing and Availability
Get a quote for 5925-01-207-0910 circuit breakerManufacturer Part Numbers and Alternates
MPN manufacturer part number | Registrant or Supplier |
---|---|
UPG-1-1REC2-62F-502-90 | Sensata Technologies Maryland, Inc |
JA1-A14-A-5-2 | Eaton Corp |
UPG-1-1REC2-62F-502-90 | Sensata Technologies Maryland, Inc |
JA1-A14-A-5-2 | Eaton Corp |
UPG-1-1REC2-62F-502-90 | Sensata Technologies Maryland, Inc |
JA1-A14-A-5-2 | Eaton Corp |
UPG-1-1REC2-62F-502-90 | Sensata Technologies Maryland, Inc |
JA1-A14-A-5-2 | Eaton Corp |
UPG-1-1REC2-62F-502-90 | Sensata Technologies Maryland, Inc |
JA1-A14-A-5-2 | Eaton Corp |
UPG-1-1REC2-62F-502-90 | Sensata Technologies Maryland, Inc |
JA1-A14-A-5-2 | Eaton Corp |
UPG-1-1REC2-62F-502-90 | Sensata Technologies Maryland, Inc |
JA1-A14-A-5-2 | Eaton Corp |
UPG-1-1REC2-62F-502-90 | Sensata Technologies Maryland, Inc |
JA1-A14-A-5-2 | Eaton Corp |
UPG-1-1REC2-62F-502-90 | Sensata Technologies Maryland, Inc |
JA1-A14-A-5-2 | Eaton Corp |
UPG-1-1REC2-62F-502-90 | Sensata Technologies Maryland, Inc |
JA1-A14-A-5-2 | Eaton Corp |
UPG-1-1REC2-62F-502-90 | Sensata Technologies Maryland, Inc |
JA1-A14-A-5-2 | Eaton Corp |